ICSI pipettes, micromanipulation

Sunlight Medical injection and containment pipettes, blastomere biopsy and polar body biopsy pipettes.

Their general shape and the configuration of their end are specifically designed to ensure smooth and seamless movement of their contents:

  • Unit packaging in a box of 10 units.
  • Made of borosilicate glass.
  • Sterilization by irradiation.

Injection pipettes (blue packaging) available in 20° and 30° angles :

Injection pipettes are used to perform intracytoplasmic sperm injection (ICSI).
Their general shape and tip configuration are specifically designed to ensure smooth and fluid movement of their contents. Multiple sperm can be loaded to inject several oocytes simultaneously. The short, thin and incisive tip allows for easy and atraumatic penetration of the oocyte.

Containment pipettes (yellow packaging) available in 20° and 30° angles :

Holding pipettes are used to maintain an oocyte or embryo in a stable position during ICSI or any other micromanipulation procedure.
The internal diameter of the standard series is 20 µm, with an external diameter of 100 µm (or 120 µm upon request).

Blastomere biopsy pipettes (red packaging) with 20° beveled angle and 30° flat angle :

Blastomere biopsy pipettes are designed for collecting embryonic blastomeres for preimplantation genetic diagnosis (PGD).

Polar body biopsy pipettes (purple packaging) at a 20° angle :

Polar body biopsy pipettes are used to remove polar bodies from human oocytes or embryos for preimplantation genetic diagnosis.
With an internal diameter of 15 µm, they can also be used in biobanking research for the transfer of murine embryonic stem cells.

 

Injection pipettes :

  • Angle of curvature: 20° or 30°
  • Inner diameter : 4.5-5.0 µm
  • Outer diameter: 7 µm
  • End-angle length: 0.55 mm

Containment pipettes :

  • Angle 20° or 30°
  • Inner diameter : 15-20 µm
  • Outer diameter : 100-119 µm or 120-130 µm (on request)
  • End-angle length: 0.65 mm

Blastomere biopsy pipettes :

  • Flat angle 30° or beveled angle 20° (on request)
  • Inner diameter : 28-32 µm
  • Outer diameter : 31-35 µm
    Tip-to-angle length : 0.55 mm Polar body biopsy pipettes, 20° angle with spike, Inner diameter : 15 µm

 

  • 022166 – Injection pipette – 20° angle – Quantity: 10
  • 022167 – Injection pipette – 30° angle – Quantity: 10
  • 022168 – Containment pipette – outer diameter 100 µm – angle 20° – Quantity: 10
  • 022169 – Containment pipette – outer diameter 100 µm – angle 30° – Quantity: 10
  • 022170 – Containment pipette – outer diameter 120 µm – angle 20° – Quantity: 10
  • 022171 – Containment pipette – outer diameter 120 µm – angle 30° – Quantity: 10
  • 022172 – Blastomere biopsy pipette – 30° angle – Quantity: 10
  • 028209 – Micropipette for blastomere biopsy – 20° beveled angle – Quantity: 10
  • 030122 – Polar body biopsy micropipette – 20° angle – Quantity: 10

 